Apartment Bathrooms

Description
- Bathroom renovations are critical for residents’ health and well-being. Quality finishes and fixtures improve the overall quality of the apartment while reducing indoor air pollution from mold and excessive moisture that could harm finishes outside the bathroom space. Thoughtful layouts contribute to an efficient use of space, finishes are chosen for durability, ease of maintenance, and adequate attic stock in the event replacement is required. GFCI outlets are required.
- Bathrooms must be designed with accessibility in mind. Because the size of NYCHA bathrooms poses a challenge to meet all ADA requirements as specified in federal ADA / UFAS standards, any conflicts with ADA / UFAS the VCA, is the controlling document, designers must include accessibility features including appropriate turn angles and door widths for the mobility impaired. Grab bars should be installed along with accessible basins. New fixtures should comply with UFAS, utilizing the UFAS Accessibility Checklist, HPD Accessibility Guide, and ADA standards.
Baseline
Overall
- All surfaces to be durable and cleanable to help with pest management and discourage mold growth.
- Piping under lavatories and sinks open to below must be insulated, enclosed, or configured to prevent contact.
- Provide a GFCI outlet in wet locations according to code.
- Use cement board, fiber cement board, or other waterproof surfaces for floors (where appropriate), walls, and ceilings (where appropriate). [COMPMOD]
- This proposal does not take into consideration limited chase space and discharge volume into existing system, an additional waste line would be required for washer discharge.
- All exposed water supply and drain pipes under lavatories and kitchen sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks
Floors
- Bathroom floors should have ceramic or porcelain tiles with a 4″ cove base. Porcelain is better for wet environments so can be used as an option based on cost effectiveness.
- Floor tiles are typically 2×2-inch but can vary as per project requirements.
- Floor tile to be waterproof and slip-resistant. [COMPMOD]
Walls
- Use cement board, fiber cement board or the equivalent meeting ASTM #D3273 for all wet wall backing.
- Walls are not to be tiled.
Ceilings
- Ceilings to be painted with mold-resistant paint. [COMPMOD]
Bathrooms
- Bathtubs are required to be standard cast-iron enamel with a push pop-up drain stopper with overflow and water-saving showerhead.
- Bathtub walls must be fitted with a fiberglass tub surround. If a tub surround is installed at a window, use a 3- to 5-piece trim kit.
- Provide fiberglass tub surround, seamless or with waterproof seams, and with no protruding elements. Lesson Learned: the protruding soap dishes on some shower surrounds are prone to cracking and have caused mold and moisture problems at multiple NYCHA properties. [COMPMOD]
- Bathtubs must be equipped with a removable in-tub seat or a permanent seat at the head end of the tub or Swivel Tub Transfer Bench.
- Consider UFAS standards. This requires a raised shower stall with ramp.
Sinks
- ADA adaptable 20-inch (W) x 19-inch (D) vitreous china sinks are required.
Toilets
- Provide floor-mounted toilets a maximum of 27 inches from the rear wall, and the water closet flange shall be installed 12 inches from the finished back wall. The centerline of the water closet shall be 16 inches minimum to 18 inches maximum from the side wall.
- Toilets must have a MaP rating of 500.
Fixtures
- Provide 20-gauge 304 polished stainless steel curtain rod.
- Above the sink, provide a soap dish and toothbrush holder, a 28-inch (H) x 18-inch (W) surface-mounted medicine cabinet with mirror, and an LED light fixture.
- Provide toilet paper holder and towel rod.
- Specify fixtures that comply with UFAS and ADA standards.
- Provide a minimum of five grab bars to meet accessibility requirements as specified by ADA standards. Grab bars should be located at appropriate heights with ¾” plywood or metal plate between studs for secure attachment (see A-DG_Bathroom Diagram). Provide blocking in all units including non-ADA units.
Stretch
- Install ultra-high efficiency toilets (0.8 gpf).
- Provide mechanically vented exhaust in all bathrooms. Exhaust fans perform significantly better than relying on operable windows alone. If a window unit includes an integrated exhaust fan, ensure the window can still be opened for fresh air. Consider placing the fan and light on separate switches to give residents more control and reduce unnecessary wear on the fan.
- This recommendation assumes that some bathrooms may not currently have functioning mechanical exhaust. Bathrooms are typically vented either by a window or by a ducted system connected to a roof fan. Mold issues are often the result of poor fan performance, inadequate airflow, or clogged duct lines, rather than the absence of mechanical ventilation. [COMPMOD]
- Provide rear‑discharge toilets and route waste piping within the wall, eliminating exposed waste lines from the floor above. Rear‑discharge fixtures allow maintenance and replacement without needing access to the apartment below. This approach requires deepening the chase wall and replacing the existing waste line riser to accommodate the revised piping layout. [COMPMOD]
- Install extra‑large or multiple surface‑mounted medicine cabinets to provide adequate bathroom storage for residents. Lessons learned: under‑sink vanity cabinets often create maintenance issues and are not preferred. Medicine cabinets are surface‑mounted, recessed installation is not feasible due to limited wall depth. [COMPMOD]
- Provide a minimum 4-inch backsplash above the sink countertop to protect the wall surface from moisture. Note that this approach may increase the cost and complexity of future repairs within the chase due to the added tile work. [COMPMOD]
- Provide wider sinks with counters from 28 inches to 40 inches depending on available space, with integral space for tenant-supplied soap dishes and toothbrush holders, instead of the wall-mounted accessories. Standard sized bathrooms are 5’x7’ nominally, in actuality it’s closer to +/- 4’-10 ½” x 6’-10 ½”, tub size and toilet space is limiting sink size without a major renovation. [COMPMOD]
- Install ultra-high efficiency water-saving fixtures. [SA]
- Stop and prevent building plumbing systems leakage. [SA]
- Upgrade mechanical ventilation systems for mold prevention. [SA]
RAD Conversions
General
- Evaluate all plumbing lines and ensure proper allowance for % repair or replacement if full replacement is not required.
- Wall-mounted vanities will only be accepted in apartments where they are the existing vanity type. Residents should be engaged on preferences related to storage and exposed plumbing to determine vanity style.
Flooring
- Bathrooms should be tiled with porcelain or ceramic tiles; products should meet Enterprise Green Communities requirements.
Walls
- Walls should be evaluated for moisture using a moisture meter. In any location that would measure wet and/or require replacement of sheetrock, paperless sheetrock must be used as replacement.
Fixtures
- All new plumbing fixtures should be low-flow and comply with efficiency rates set by Local Law 57 and Enterprise Green Communities Criteria.
Relevant Codes & Regulations
NYC Plumbing Code – Chapter 4
Fixtures, faucets, and fixture fittings requirements
ADA Standards – Toilet and Bathing Facilities
Accessibility requirements for residential bathrooms
NYC Building Code – Chapter 12
Interior environment requirements including ventilation
WaterSense Specification
EPA water efficiency standards for plumbing fixtures
NYC Local Law 84 – Water Fixtures
Water conservation requirements for plumbing fixtures